A practical reference on REV-ERB agonist: what it is, how it behaves, what the literature reports, and where the honest uncertainties sit.
This page was last updated on 2026-05-07 and is reviewed periodically as new material appears.
SR9009 is a synthetic small molecule studied as an agonist of the nuclear receptors REV-ERBα and REV-ERBβ. It is not an approved medicine and has no established human therapeutic use. The compound appears in scientific literature as a tool for probing circadian and metabolic regulation. Online sellers often label it as a research chemical, sometimes using the nickname Stenabolic. Its chemical identity is distinct from selective androgen receptor modulators, stimulants, and peroxisome proliferator-activated receptor delta agonists. Researchers use it mainly in cell and animal experiments.
At the molecular level, SR9009 binds REV-ERBα and REV-ERBβ and alters their repressive activity on target genes. These nuclear receptors help regulate the circadian clock, lipid synthesis, glucose metabolism, and inflammatory pathways. By changing transcription, the compound can shift the timing or magnitude of downstream metabolic processes in model systems. It does not act through androgen receptors or adenosine receptors, which distinguishes it from several substances sold for athletic performance. Whether the same transcriptional changes occur in humans at tolerable exposures remains an open question because controlled human studies are lacking.
SR9009 is a synthetic small molecule studied as an agonist of the nuclear receptors REV-ERBα and REV-ERBβ. It is not a steroid, peptide, or natural hormone. In scientific literature, it appears under the code SR9009 and in non-scientific contexts as Stenabolic. The compound was identified through chemical screening efforts aimed at targeting circadian clock components. Its status remains investigational, and no regulatory agency has approved it as a human medicine.
REV-ERB proteins help regulate daily cycles in gene expression, including genes tied to lipid and glucose metabolism. SR9009 binds these receptors and alters their activity in cell and animal experiments. Consequences observed in rodents include changes in skeletal muscle oxidative capacity, blood lipid levels, and exercise performance. The precise chain from receptor occupancy to whole-body effects is still an active area of study. Human responses cannot be assumed from rodent data.
Most published work on SR9009 consists of preclinical studies. It is widely sold as a research chemical, a category that does not imply safety, efficacy, or pharmaceutical-grade quality. Sports anti-doping organizations have listed SR9009 as a prohibited substance, and its presence in an athlete sample can lead to sanctions. Legal status differs by country; in several jurisdictions it is not approved for human consumption and may be treated as an unapproved new drug.
| Property | Value | Notes |
|---|---|---|
| Molecular formula | C20H24ClN3O4S | Derived from published structure. |
| Molecular weight | 437.94 g/mol | Calculated value. |
| Appearance | White to off-white solid | Typical for purified research samples. |
| Solubility | DMSO, ethanol; low in water | Class: poorly water-soluble. |
| Typical storage | -20 °C, desiccated, protected from light | Limits degradation. |
SR9009 is a synthetic small molecule studied as an agonist of REV-ERB nuclear receptors. REV-ERB alpha and REV-ERB beta help regulate circadian rhythms and metabolic gene expression. In laboratory research, SR9009 has been used to probe how these receptors affect skeletal muscle, liver, and adipose tissue. The compound was identified in academic drug-discovery work and is often described in scientific literature by its chemical name and research code. It is not an approved medicine, and human clinical data remain limited or absent.
SR9009 binds REV-ERB receptors and alters their repressive activity on target genes. This action can change transcription of genes involved in lipid handling, glucose metabolism, and mitochondrial function. In rodent studies, treated animals have shown changes in muscle oxidative capacity and exercise performance, though effects vary by dose, duration, and model. The precise molecular steps connecting receptor binding to whole-body outcomes are still an active area of investigation. Findings in animals do not automatically translate to humans.
Laboratory samples of SR9009 are typically handled as research chemicals rather than pharmaceuticals. Suppliers usually state that the material is for research use only and not for human or veterinary administration. Storage recommendations generally call for a freezer at approximately −20 °C, protection from light, and a desiccated environment. The solid is often described as a white to off-white powder. Solubility is commonly reported in organic solvents such as dimethyl sulfoxide and ethanol, with low solubility in water.
Analytical identification and purity assessment often use high-performance liquid chromatography with ultraviolet detection or mass spectrometry. Liquid chromatography–tandem mass spectrometry is used to detect and quantify SR9009 in biological matrices, including urine and blood, for anti-doping or pharmacokinetic studies. Nuclear magnetic resonance spectroscopy can confirm molecular structure. Stability depends on form and storage: the solid is generally more stable than solutions, and repeated freeze–thaw cycles may degrade samples. Purity is typically reported as a percentage from a certificate of analysis.
Storage conditions for research-grade SR9009 generally involve a freezer at approximately minus twenty degrees Celsius, sometimes lower for long-term preservation. Containers should remain tightly closed and protected from light. Desiccants may be used to limit moisture uptake. Solutions are often stored in aliquots to avoid repeated warming and cooling. Stability data for the compound under various conditions are limited, so laboratories typically follow supplier recommendations and verify performance through periodic analytical checks rather than assuming indefinite stability.
Identity and purity testing for SR9009 commonly uses liquid chromatography coupled with tandem mass spectrometry. This method separates the compound from matrix components and detects it by mass-to-charge transitions, providing sensitive and specific confirmation. Nuclear magnetic resonance spectroscopy can support structural identification, while high-performance liquid chromatography with ultraviolet detection may estimate purity. Because online products labeled as SR9009 may contain other substances or no active compound at all, independent verification is important in research settings. Certificates of analysis are useful but not a substitute for in-house testing.
Regulatory status varies by country and intended use. Major drug agencies have not granted marketing authorization for SR9009 as a medicine, and it is not listed as a controlled substance in many jurisdictions. It is often sold as a research chemical, a category that may fall outside pharmaceutical manufacturing rules. Buyers should verify local laws and supplier documentation, including certificates of analysis. The lack of standardized quality controls raises concerns about identity, purity, and actual content in products marketed online.
In laboratory settings, SR9009 is commonly identified by its molecular structure and its interaction with REV-ERB receptors. Vendors may list it under synonyms such as Stenabolic or REV-ERB agonist, but those names do not define purity or identity. Analytical confirmation typically uses high-performance liquid chromatography with ultraviolet detection or liquid chromatography–mass spectrometry. A reference standard is needed to compare retention time and mass spectrum, because the compound can be confused with related research chemicals.
Handling practices for SR9009 focus on minimizing degradation and contamination. The solid is generally stored desiccated at or below -20 °C, protected from light and moisture. Stock solutions are often prepared in dimethyl sulfoxide or ethanol, then aliquoted to avoid repeated freeze–thaw cycles. Aqueous solubility is low, so formulations for animal studies may require cosolvents or suspending agents. Personnel should follow institutional chemical safety procedures, because toxicological data for humans are incomplete.
=== Prewar and postwar eras === The club came close to reaching the First Division in their early years. In the 1921–22 season, they missed out on promotion by goal difference. During the 1930s and 1940s years, the club found themselves sliding between the Second and Third Division. In 1949, the club signed Danny Blanchflower from Glentoran, and he impressed at Oakwell that two years later he was signed by First Division side Aston Villa, later signing for Tottenham Hotspur and being voted FWA Player of the Year twice, as well as being the captain of the 20th century's first league and cup double winning team in 1960–61. Around the time of Blanchflower's departure, a young centre-forward called Tommy Taylor broke into the Barnsley team, scoring 26 goals in 44 games. In April 1953, he became one of the most expensive players in English football at the time when Sir Matt Busby signed him for Manchester United for a fee of £29,999. Taylor went on to be a prolific goalscorer at the highest level over the next five years, winning two league titles and scoring 16 goals in 19 appearances for the England national football team, before losing his life in the Munich air disaster on 6 February 1958. When the Northern and Southern sections of the Third Division were replaced by national Third and Fourth Divisions for the 1958–59 season, Barnsley were still in the Second Division, but went down to the Third Division at the end of the season. In 1965, Barnsley were relegated to the Football League Fourth Division for the first time, winning promotion three years later.
=== Histopathology === There is a significant overlap between cholestasis resulting from a hepatocellular origin and cholestasis caused by bile duct obstruction. Due to this, obstructive cholestasis can only be diagnosed after finding additional diagnostic signs that are specific to obstructive changes to the bile ducts or portal tracts. In both non-obstructive and obstructive cholestasis, there is an accumulation of substances that are typically secreted in the bile, as well as degeneration of hepatocytes. The most significant feature from a histopathological perspective includes pigmentation resulting from the retention of bilirubin. Under a microscope, the individual hepatocytes will have a brownish-green stippled appearance within the cytoplasm, representing bile that cannot get out of the cell. Pigmentation can involve regurgitation of bile into the sinusoidal spaces caused by phagocytosis from Kupffer cells, an accumulation of bilirubin within hepatocytes, and inspissated bile in the canaliculi. Most pigmentation and canaliculi dilation occurs in the perivenular region of the hepatic lobule. In chronic cases, this may extend into the periportal area. Hepatocyte necrosis is not a significant feature of cholestasis; however, apoptosis may often occur. Under the microscope, hepatocytes in the perivenular zone appear enlarged and flocculent. In cases of obstructive cholestasis, bile infarcts may be produced during the degeneration and necrosis of hepatocytes. Bile infarcts are marked by a large amount of pigmented tissue surrounded by a ring of necrotic hepatocytes.
=== Ancient Cambodian glaze === Research on Khmer Antique glazing and techniques - Antique Khmer ceramics are renowned, but the technology was lost during the recent terrible upheavals in Cambodia (Khmer Rouge). The center has sought to rediscover this technology, researching antique Khmer glazing, bisque, kilns, potters language etc.
Sources: en.wikipedia.org
===== First generation ===== The Cronin–Gerow Implant, prosthesis model 1963, was a silicone rubber envelope-sac, shaped like a teardrop, which was filled with viscous silicone-gel. To reduce the rotation of the emplaced breast implant upon the chest wall, the model 1963 prosthesis was affixed to the implant pocket with a fastener-patch, made of Dacron material (polyethylene terephthalate), which was attached to the rear of the breast implant shell.
== Spectrophotometry in Print == To those involved in the graphics field, color is a property of the surface of a given object under a certain illumination or light source. In order to reproduce the same color or design, the sample color must be measured. This is where spectrophotometers come in. Different types of spectrophotometers are used for different printing technologies. Offset presses use handheld and closed-loop scanning spectrophotometers. Flexo, rotogravure, screen printers, and digital presses use handheld and inline spectrophotometers. The human eye, as well as the brain, can struggle with color perception/vision. Some individuals may experience color blindness, while others will notice that their eyes become strained and less apt to see color effectively as the day goes on. To combat these issues, spectrophotometers can be used to measure color targets and control color strips. In the printing industry, the three types of spectrophotometers are: Handheld, handheld with informational displays, and automated. Another device is a spectrodensitometer, which can calculate density readings from spectral values. From its definition, a spectrodensitometer is "A spectrally based densitometer that combines the functions of a spectrophotometer, colorimeter, and densitometer."
These errors were later corrected by the independent synthetic efforts of researchers at Tohoku University and Harvard University. In 1997, en route to the originally reported structure, researchers under the direction of Masahiro Hirama discovered that the spectroscopic data of the proposed chloroazatyrosyl (S)-α-amino acid derivative were not consistent with those of the degradation product characterized by Leet et al. Instead, an (R)-β-amino acid derivative was proposed and validated by the Hirama group. This revision led Hirama et al. to invert the other aglycone stereocenters as well, affording a revised structure of kedarcidin chromophore that differed only in the relative stereochemistry of the mycarose-bearing carbon, C10. Finally, in 2007, Myers and co-workers synthesized the structure proposed by Hirama et al.; the corresponding NMR spectroscopic data were distinct from that of the natural product, leading the Myers group to revise the stereochemistry of the mycarose-bearing carbon to 10-(S).
Sources: en.wikipedia.org
=== Animal sources === Animal-sourced foods do not generally provide much vitamin C, and what there is, is largely destroyed by heat during cooking. For example, raw chicken liver contains 17.9 mg/100 g, but fried, the content is reduced to 2.7 mg/100 g. Vitamin C is present in human breast milk at 5.0 mg/100 g. Cow's milk contains 1.0 mg/100 g, but the heat of pasteurization destroys it.
==== Adherence ==== Poor compliance with medications and follow-up visits are a major reason for treatment failure and disease progression in glaucoma patients. Poor adherence could lead to increased complication rates, thus increasing the need for non-pharmacological interventions, including surgery. Patient education and communication must be ongoing to sustain successful treatment plans for this lifelong disease with no early symptoms.
The metabolism of HMB is catalyzed by an uncharacterized enzyme which converts it to β-hydroxy β-methylbutyryl-CoA (HMB-CoA). HMB-CoA is metabolized by either enoyl-CoA hydratase or another uncharacterized enzyme, producing β-methylcrotonyl-CoA (MC-CoA) or hydroxymethylglutaryl-CoA (HMG-CoA) respectively. MC-CoA is then converted by the enzyme methylcrotonyl-CoA carboxylase to methylglutaconyl-CoA (MG-CoA), which is subsequently converted to HMG-CoA by methylglutaconyl-CoA hydratase. HMG-CoA is then cleaved into acetyl-CoA and acetoacetate by HMG-CoA lyase or used in the production of cholesterol via the mevalonate pathway.
Sources: en.wikipedia.org
SR9009 is a synthetic REV-ERB agonist used in laboratory research. It is not an approved drug, and its effects in humans are not well characterized. It is often sold as a research chemical under the name Stenabolic.
No. SR9009 targets the nuclear receptors REV-ERBα and REV-ERBβ, not the androgen receptor. This mechanism differs from selective androgen receptor modulators and from exercise mimetics that act on PPARδ.
Published evidence is mainly preclinical, using cell cultures and animal models. Controlled human trials are not well documented in the public literature. Claims about human performance or health effects therefore remain unsupported by robust clinical data.
It is a synthetic compound studied as an agonist of REV-ERB nuclear receptors. It is not an approved medicine and has mainly been examined in laboratory and animal research.